Glaucoma Drainage Implants
"Glaucoma Drainage Implants" is a descriptor in the National Library of Medicine's controlled vocabulary thesaurus,
MeSH (Medical Subject Headings). Descriptors are arranged in a hierarchical structure,
which enables searching at various levels of specificity.
Devices, usually incorporating unidirectional valves, which are surgically inserted in the sclera to maintain normal intraocular pressure.
Descriptor ID |
D020327
|
MeSH Number(s) |
E07.695.250
|
Concept/Terms |
Glaucoma Drainage Implants- Glaucoma Drainage Implants
- Drainage Implant, Glaucoma
- Drainage Implants, Glaucoma
- Glaucoma Drainage Implant
- Implant, Glaucoma Drainage
- Implants, Glaucoma Drainage
- Aqueous Shunts
- Aqueous Shunt
- Shunt, Aqueous
- Shunts, Aqueous
- Glaucoma Filtration Implants
- Filtration Implant, Glaucoma
- Filtration Implants, Glaucoma
- Glaucoma Filtration Implant
- Implant, Glaucoma Filtration
- Implants, Glaucoma Filtration
- Aqueous Humor Shunts
- Aqueous Humor Shunt
- Shunt, Aqueous Humor
- Shunts, Aqueous Humor
|
Below are MeSH descriptors whose meaning is more general than "Glaucoma Drainage Implants".
Below are MeSH descriptors whose meaning is more specific than "Glaucoma Drainage Implants".
This graph shows the total number of publications written about "Glaucoma Drainage Implants" by people in this website by year, and whether "Glaucoma Drainage Implants" was a major or minor topic of these publications.
To see the data from this visualization as text, click here.
Year | Major Topic | Minor Topic | Total |
---|
2010 | 1 | 0 | 1 | 2020 | 1 | 0 | 1 | 2021 | 2 | 0 | 2 | 2022 | 1 | 0 | 1 |
To return to the timeline, click here.
Below are the most recent publications written about "Glaucoma Drainage Implants" by people in Profiles.
-
Weber P, Amin S, Qiu M. Decompression Retinopathy after Ahmed Glaucoma Valve in a Patient with Neurofibromatosis Type 1 and Moyamoya Syndrome. Ophthalmology. 2022 07; 129(7):802.
-
Si Z, Theophanous C, Khanna S, Qiu M. Early Intraocular Pressure Control Via Capsule Revision of a Failed Valved Aqueous Shunt During Concurrent Placement of a Nonvalved Aqueous Shunt. Ophthalmol Glaucoma. 2022 Mar-Apr; 5(2):229-232.
-
Qiu M. Aqueous Shunt Revision with Autologous Capsular Patch Graft: Surgical Technique Description and Preliminary Results. Ophthalmol Glaucoma. 2021 Nov-Dec; 4(6):646-648.
-
Medert CM, Cavuoto KM, Vanner EA, Grajewski AL, Chang TC. Risk Factors for Glaucoma Drainage Device Failure and Complication in the Pediatric Population. Ophthalmol Glaucoma. 2021 Jan-Feb; 4(1):63-70.
-
Turaga K, Rao A, Ali MH, Shastry R, Choudhari N, Garudadri C, Senthil S. Safety and efficacy of paediatric silicone Ahmed glaucoma valve (AGV) in adult eyes with post-VR surgery glaucoma. Eye (Lond). 2020 06; 34(6):1121-1128.
-
Turaga K. Commentary: Aurolab aqueous drainage implant: Posterior versus anterior segment implantation. Indian J Ophthalmol. 2019 10; 67(10):1779.
-
Nascimento E Silva R, Shen LQ, Chiou CA, Shanbhag SS, Paschalis EI, Pasquale LR, Colby KA, Dohlman CH, Chodosh J, Alves MR. Glaucoma Management in Patients With Aniridia and Boston Type 1 Keratoprosthesis. Am J Ophthalmol. 2019 11; 207:258-267.
-
Senthil S, Turaga K, Mohammed HA, Krishnamurthy R, Badakere S, Dikshit S, Choudhari N, Mandal AK, Garudadri CS. Outcomes of Silicone Ahmed Glaucoma Valve Implantation in Refractory Pediatric Glaucoma. J Glaucoma. 2018 09; 27(9):769-775.
-
Senthil S, Gollakota S, Ali MH, Turaga K, Badakere S, Krishnamurthy R, Garudadri CS. Comparison of the New Low-Cost Nonvalved Glaucoma Drainage Device with Ahmed Glaucoma Valve in Refractory Pediatric Glaucoma in Indian Eyes. Ophthalmol Glaucoma. 2018 Nov - Dec; 1(3):167-174.
-
Senthil S, Turaga K, Kumar R, Sangwan VS. Challenges in the implantation of a Boston type 1 keratoprosthesis and a glaucoma drainage device in a nanophthalmic eye. BMJ Case Rep. 2014 Oct 01; 2014.
|
People  People who have written about this concept. _
Similar Concepts
People who have written about this concept.
_
Top Journals
Top journals in which articles about this concept have been published.
|