Mark Belkin to Humans
This is a "connection" page, showing publications Mark Belkin has written about Humans.
Connection Strength
0.506
-
Pulse Pressure Response to Inotrope Therapy in Cardiogenic Shock: A Subanalysis of the DOREMI Trial. JACC Heart Fail. 2024 Jun; 12(6):1126-1127.
Score: 0.032
-
Letter by Shahriar et al Regarding Article, "Protocolized Natriuresis-Guided Decongestion Improves Diuretic Response in Acute Heart Failure: The Multicenter ENACT-HF Study". Circ Heart Fail. 2024 May; 17(5):e011703.
Score: 0.032
-
The Veterans Affairs' Dashboard Confessional: Vindication of the VA HF Dashboard. J Card Fail. 2024 Mar; 30(3):460-461.
Score: 0.031
-
Standardization of the Right Heart Catheterization and the Emerging Role of Advanced Hemodynamics in Heart Failure. J Card Fail. 2023 11; 29(11):1543-1555.
Score: 0.030
-
Sex-Based Differences in Hemodynamic Response to Inotropes: A Subanalysis of the DOREMI Trial. JACC Heart Fail. 2023 09; 11(9):1275-1277.
Score: 0.030
-
Management of Heart Failure. JAMA. 2022 10 04; 328(13):1346-1347.
Score: 0.028
-
Should We Be Using Aortic Pulsatility Index Over Cardiac Power Output in Heart Failure Cardiogenic Shock? Circ Heart Fail. 2022 07; 15(7):e009601.
Score: 0.028
-
Physiology and Clinical Utility of HeartMate Pump Parameters. J Card Fail. 2022 05; 28(5):845-862.
Score: 0.027
-
Improved Prognostic Performance of Cardiac Power Output With Right Atrial Pressure: A Subanalysis of the ESCAPE Trial. J Card Fail. 2022 05; 28(5):866-869.
Score: 0.026
-
A composite metric for predicting benefit from spironolactone in heart failure with preserved ejection fraction. ESC Heart Fail. 2021 10; 8(5):3495-3503.
Score: 0.026
-
Aortic Pulsatility Index: A Novel Hemodynamic Variable for Evaluation of Decompensated Heart Failure. J Card Fail. 2021 10; 27(10):1045-1052.
Score: 0.026
-
Aortic pulsatility index predicts clinical outcomes in heart failure: a sub-analysis of the ESCAPE trial. ESC Heart Fail. 2021 04; 8(2):1522-1530.
Score: 0.025
-
Left Ventricular Assist Device Performance Under Pressure: Troubleshooting Outflow Graft Dysfunction. Circ Heart Fail. 2020 07; 13(7):e007098.
Score: 0.024
-
Heart health in the age of highly active antiretroviral therapy: a review of HIV cardiomyopathy. Curr Opin Cardiol. 2018 05; 33(3):317-324.
Score: 0.021
-
Incidence and Clinical Significance of New-Onset Device-Detected Atrial Tachyarrhythmia: A Meta-Analysis. Circ Arrhythm Electrophysiol. 2018 03; 11(3):e005393.
Score: 0.020
-
Does Cardiac Resynchronization Therapy Benefit Patients with Non-Left Bundle Branch Block Prolonged QRS Patterns? Curr Cardiol Rep. 2017 10 24; 19(12):125.
Score: 0.020
-
PREDICT HF: Risk stratification in advanced heart failure using novel hemodynamic parameters. Clin Cardiol. 2024 Jun; 47(6):e24277.
Score: 0.008
-
Development and Validation of a Risk Score Predicting Death Without Transplant in Adult Heart Transplant Candidates. JAMA. 2024 02 13; 331(6):500-509.
Score: 0.008
-
Hemodynamic Consequences of Long-Term Continuous Flow: The Importance of the Right Ventricular-Aortic Valve Interactions. Circ Heart Fail. 2023 10; 16(10):e010713.
Score: 0.007
-
Adverse Hemodynamic Consequences of Continuous Left Ventricular Mechanical Support: JACC Review Topic of the Week. J Am Coll Cardiol. 2023 07 04; 82(1):70-81.
Score: 0.007
-
Status One and Status Two Exception Use in the Updated Heart Allocation System. J Card Fail. 2023 06; 29(6):963-967.
Score: 0.007
-
Selection of percutaneous mechanical circulatory support in cardiogenic shock: patient-specific considerations and insights from contemporary clinical data. Curr Opin Cardiol. 2023 01 01; 38(1):47-53.
Score: 0.007
-
The prognostic role of advanced hemodynamic variables in patients with left ventricular assist devices. Artif Organs. 2023 Mar; 47(3):574-581.
Score: 0.007
-
Management of Pulmonary Mucormycosis After Orthotopic Heart Transplant: A Case Series. Transplant Proc. 2021 Dec; 53(10):3051-3055.
Score: 0.007
-
Left Ventricular Pressure Ratio Predicts In-Hospital Outcomes in Hospitalized Heart Failure With Reduced Ejection Fraction. J Invasive Cardiol. 2021 Jul; 33(7):E507-E515.
Score: 0.006
-
Anatomic Description of Tricuspid Apparatus Interference From Implantable Intracardiac Devices. JACC Cardiovasc Imaging. 2022 02; 15(2):361-365.
Score: 0.006
-
High sensitivity Troponin-T for prediction of adverse events in patients with COVID-19. Biomarkers. 2020 Dec; 25(8):626-633.
Score: 0.006
-
Weighted versus uniform dose of tranexamic acid in patients undergoing primary, elective knee arthroplasty: a prospective randomized controlled trial. J Arthroplasty. 2014 Sep; 29(9 Suppl):186-8.
Score: 0.004