Ioannis Koktzoglou to Female
This is a "connection" page, showing publications Ioannis Koktzoglou has written about Female.
Connection Strength
0.734
-
Equilibrium phase contrast-enhanced magnetic resonance angiography of the thoracic aorta and heart using balanced T1 relaxation-enhanced steady-state. J Cardiovasc Magn Reson. 2024 Winter; 26(2):101046.
Score: 0.044
-
Quantitative Time-of-Flight Head Magnetic Resonance Angiography of Cerebrovascular Disease. J Magn Reson Imaging. 2025 Jan; 61(1):404-412.
Score: 0.044
-
Dark Blood Contrast-Enhanced Brain MRI Using Echo-uT1RESS. J Magn Reson Imaging. 2024 Aug; 60(2):789-797.
Score: 0.042
-
Dark blood cardiovascular magnetic resonance of the heart, great vessels, and lungs using electrocardiographic-gated three-dimensional unbalanced steady-state free precession. J Cardiovasc Magn Reson. 2021 11 01; 23(1):127.
Score: 0.037
-
Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance. J Cardiovasc Magn Reson. 2018 02 19; 20(1):12.
Score: 0.029
-
Radial fast interrupted steady-state (FISS) magnetic resonance imaging. Magn Reson Med. 2018 04; 79(4):2077-2086.
Score: 0.028
-
Nonenhanced MR angiography of the pulmonary arteries using single-shot radial quiescent-interval slice-selective (QISS): a technical feasibility study. J Cardiovasc Magn Reson. 2017 Jun 30; 19(1):48.
Score: 0.027
-
Super-resolution intracranial quiescent interval slice-selective magnetic resonance angiography. Magn Reson Med. 2018 02; 79(2):683-691.
Score: 0.027
-
Improved dark blood imaging of the heart using radial balanced steady-state free precession. J Cardiovasc Magn Reson. 2016 Oct 19; 18(1):69.
Score: 0.026
-
Quiescent interval low angle shot magnetic resonance angiography of the extracranial carotid arteries. Magn Reson Med. 2016 May; 75(5):2072-7.
Score: 0.024
-
Ungated radial quiescent-inflow single-shot (UnQISS) magnetic resonance angiography using optimized azimuthal equidistant projections. Magn Reson Med. 2014 Dec; 72(6):1522-9.
Score: 0.023
-
Projection MR imaging of peripheral arterial calcifications. Magn Reson Med. 2015 May; 73(5):1939-45.
Score: 0.022
-
Nonenhanced arterial spin labeled carotid MR angiography using three-dimensional radial balanced steady-state free precession imaging. J Magn Reson Imaging. 2015 Apr; 41(4):1150-6.
Score: 0.022
-
4D Dark blood arterial wall magnetic resonance imaging: methodology and demonstration in the carotid arteries. Magn Reson Med. 2013 Apr; 69(4):956-65.
Score: 0.020
-
Quiescent-inflow single-shot magnetic resonance angiography using a highly undersampled radial k-space trajectory. Magn Reson Med. 2013 Dec; 70(6):1662-8.
Score: 0.020
-
Nonenhanced extracranial carotid MR angiography using arterial spin labeling: improved performance with pseudocontinuous tagging. J Magn Reson Imaging. 2011 Aug; 34(2):384-94.
Score: 0.018
-
Highly accelerated contrast-enhanced MR angiography: improved reconstruction accuracy and reduced noise amplification with complex subtraction. Magn Reson Med. 2010 Dec; 64(6):1843-8.
Score: 0.017
-
Quiescent-interval single-shot unenhanced magnetic resonance angiography of peripheral vascular disease: Technical considerations and clinical feasibility. Magn Reson Med. 2010 Apr; 63(4):951-8.
Score: 0.017
-
Fully automated reconstruction of ungated ghost magnetic resonance angiograms. J Magn Reson Imaging. 2010 Mar; 31(3):655-62.
Score: 0.016
-
Ghost magnetic resonance angiography. Magn Reson Med. 2009 Jun; 61(6):1515-9.
Score: 0.016
-
Fast projective carotid MR angiography using arterial spin-labeled balanced SSFP. J Magn Reson Imaging. 2008 Sep; 28(3):778-82.
Score: 0.015
-
Dark-blood MRI of the thoracic aorta with 3D diffusion-prepared steady-state free precession: initial clinical evaluation. AJR Am J Roentgenol. 2007 Oct; 189(4):966-72.
Score: 0.014
-
Three-dimensional black-blood MR imaging of carotid arteries with segmented steady-state free precession: initial experience. Radiology. 2007 Apr; 243(1):220-8.
Score: 0.013
-
Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls. J Cardiovasc Magn Reson. 2007; 9(1):33-42.
Score: 0.013
-
Multislice dark-blood carotid artery wall imaging: a 1.5 T and 3.0 T comparison. J Magn Reson Imaging. 2006 May; 23(5):699-705.
Score: 0.013
-
Coronary artery wall imaging: initial experience at 3 Tesla. J Magn Reson Imaging. 2005 Feb; 21(2):128-32.
Score: 0.012
-
Improved visualization of intracranial distal arteries with multiple 2D slice dynamic ASL-MRA and super-resolution convolutional neural network. Magn Reson Med. 2024 Dec; 92(6):2491-2505.
Score: 0.011
-
High-resolution, non-contrast-enhanced magnetic resonance angiography of the wrist, hand and digital arteries using optimized implementation of Cartesian quiescent interval slice selective (QISS) at 1.5 T. Magn Reson Imaging. 2021 05; 78:58-68.
Score: 0.009
-
Radial-based acquisition strategies for pre-procedural non-contrast cardiovascular magnetic resonance angiography of the pulmonary veins. J Cardiovasc Magn Reson. 2020 11 30; 22(1):78.
Score: 0.009
-
Free-Breathing Fast Low-Angle Shot Quiescent-Interval Slice-Selective Magnetic Resonance Angiography for Improved Detection of Vascular Stenoses in the Pelvis and Abdomen: Technical Development. Invest Radiol. 2019 12; 54(12):752-756.
Score: 0.008
-
Dynamic quantitative nonenhanced magnetic resonance angiography of the abdominal aorta and lower extremities using cine fast interrupted steady-state in combination with arterial spin labeling: a feasibility study. J Cardiovasc Magn Reson. 2019 09 02; 21(1):55.
Score: 0.008
-
Non-Contrast-Enhanced Carotid MRA: Clinical Evaluation of a Novel Ungated Radial Quiescent-Interval Slice-Selective MRA at 1.5T. AJNR Am J Neuroradiol. 2019 09; 40(9):1529-1537.
Score: 0.008
-
Non-contrast-enhanced magnetic resonance imaging for visualization and quantification of endovascular aortic prosthesis, their endoleaks and aneurysm sacs at 1.5?T. Magn Reson Imaging. 2019 07; 60:164-172.
Score: 0.008
-
Feasibility of Image Fusion for Concurrent MRI Evaluation of Vessel Lumen and Vascular Calcifications in Peripheral Arterial Disease. AJR Am J Roentgenol. 2019 04; 212(4):914-918.
Score: 0.008
-
Single-Shot Coronary Quiescent-Interval Slice-Selective Magnetic Resonance Angiography Using Compressed Sensing: A Feasibility Study in Patients With Congenital Heart Disease. J Comput Assist Tomogr. 2018 Sep-Oct; 42(5):739-746.
Score: 0.007
-
Cardiovascular magnetic resonance imaging of aorto-iliac and ilio-femoral vascular calcifications using proton density-weighted in-phase stack of stars. J Cardiovasc Magn Reson. 2018 08 06; 20(1):51.
Score: 0.007
-
Noncontrast Hybrid Arterial Spin-Labeled Imaging of the Intracranial Arteries. J Comput Assist Tomogr. 2017 Nov/Dec; 41(6):854-860.
Score: 0.007
-
MR imaging of iliofemoral peripheral vascular calcifications using proton density-weighted, in-phase three-dimensional stack-of-stars gradient echo. Magn Reson Med. 2017 06; 77(6):2146-2152.
Score: 0.006
-
Evaluating peripheral arterial disease with unenhanced quiescent-interval single-shot MR angiography at 3 T. AJR Am J Roentgenol. 2014 Apr; 202(4):886-93.
Score: 0.005
-
Renal perfusion imaging with two-dimensional navigator gated arterial spin labeling. Magn Reson Med. 2014 Feb; 71(2):570-9.
Score: 0.005
-
Optimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries. J Cardiovasc Magn Reson. 2012 May 19; 14:30.
Score: 0.005
-
Time-resolved spin-labeled balanced steady-state free precession cineangiography for visualizing intracardiac shunt: technical considerations and clinical feasibility. Magn Reson Med. 2012 Dec; 68(6):1798-806.
Score: 0.005
-
Peripheral arterial disease in a symptomatic diabetic population: prospective comparison of rapid unenhanced MR angiography (MRA) with contrast-enhanced MRA. AJR Am J Roentgenol. 2011 Dec; 197(6):1466-73.
Score: 0.005
-
Evaluation of peripheral arterial disease with nonenhanced quiescent-interval single-shot MR angiography. Radiology. 2011 07; 260(1):282-93.
Score: 0.004
-
Functional MRI of liver using BOLD MRI: effect of glucose. J Magn Reson Imaging. 2010 Oct; 32(4):988-91.
Score: 0.004
-
Sub-millimeter isotropic MRI for segmentation of subcortical brain regions and brain visualization. J Magn Reson Imaging. 2010 Apr; 31(4):980-6.
Score: 0.004
-
Rapid whole-brain magnetic resonance imaging with isotropic resolution at 3 Tesla. Invest Radiol. 2009 Jan; 44(1):54-9.
Score: 0.004