Roberto M. Lang to Image Processing, Computer-Assisted

This is a "connection" page, showing publications Roberto M. Lang has written about Image Processing, Computer-Assisted.
  1. Three-Dimensional Echocardiographic Automated Quantification of Left Heart Chamber Volumes Using an Adaptive Analytics Algorithm: Feasibility and Impact of Image Quality in Nonselected Patients. J Am Soc Echocardiogr. 2017 Sep; 30(9):879-885.
    View in: PubMed
    Score: 0.377
  2. The value of three-dimensional echocardiography derived mitral valve parametric maps and the role of experience in the diagnosis of pathology. J Am Soc Echocardiogr. 2011 Aug; 24(8):860-7.
    View in: PubMed
    Score: 0.248
  3. Simultaneous real-time echocardiographic imaging of myocardial perfusion and regional function using color-encoded, contrast-enhanced power modulation. J Am Soc Echocardiogr. 2003 Dec; 16(12):1258-66.
    View in: PubMed
    Score: 0.147
  4. Innovations in transesophageal echocardiographic imaging. Echocardiography. 2003 Nov; 20(8):755-61.
    View in: PubMed
    Score: 0.146
  5. Automated endocardial border detection and evaluation of left ventricular function from contrast-enhanced images using modified acoustic quantification. J Am Soc Echocardiogr. 2002 Aug; 15(8):777-81.
    View in: PubMed
    Score: 0.134
  6. Combined assessment of myocardial perfusion and regional left ventricular function by analysis of contrast-enhanced power modulation images. Circulation. 2001 Jul 17; 104(3):352-7.
    View in: PubMed
    Score: 0.125
  7. Electronic transmission of digital echocardiographic studies: effects of MPEG compression. Int J Cardiol. 2000 Sep 15; 75(2-3):141-5.
    View in: PubMed
    Score: 0.118
  8. Machine learning based quantification of ejection and filling parameters by fully automated dynamic measurement of left ventricular volumes from cardiac magnetic resonance images. Magn Reson Imaging. 2020 04; 67:28-32.
    View in: PubMed
    Score: 0.112
  9. Use of harmonic imaging without echocardiographic contrast to improve two-dimensional image quality. Am J Cardiol. 1998 Sep 15; 82(6):794-9.
    View in: PubMed
    Score: 0.102
  10. Use of color kinesis for evaluation of left ventricular filling in patients with dilated cardiomyopathy and mitral regurgitation. J Am Coll Cardiol. 1998 Jun; 31(7):1598-606.
    View in: PubMed
    Score: 0.100
  11. Echocardiographic reference ranges for normal left atrial function parameters: results from the EACVI NORRE study. Eur Heart J Cardiovasc Imaging. 2018 06 01; 19(6):630-638.
    View in: PubMed
    Score: 0.100
  12. Echocardiographic reference ranges for normal left ventricular 2D strain: results from the EACVI NORRE study. Eur Heart J Cardiovasc Imaging. 2017 May 01; 18(8):833-840.
    View in: PubMed
    Score: 0.093
  13. Segmental analysis of color kinesis images: new method for quantification of the magnitude and timing of endocardial motion during left ventricular systole and diastole. Circulation. 1997 Apr 15; 95(8):2082-97.
    View in: PubMed
    Score: 0.093
  14. Normal Values of Left Ventricular Mass Index Assessed by Transthoracic Three-Dimensional Echocardiography. J Am Soc Echocardiogr. 2016 Jan; 29(1):51-61.
    View in: PubMed
    Score: 0.084
  15. Technical guidelines for performing automated border detection studies. J Am Soc Echocardiogr. 1995 May-Jun; 8(3):293-305.
    View in: PubMed
    Score: 0.081
  16. Mechanistic insights and characterization of sickle cell disease-associated cardiomyopathy. Circ Cardiovasc Imaging. 2014 May; 7(3):430-437.
    View in: PubMed
    Score: 0.075
  17. Characterization of degenerative mitral valve disease using morphologic analysis of real-time three-dimensional echocardiographic images: objective insight into complexity and planning of mitral valve repair. Circ Cardiovasc Imaging. 2011 Jan; 4(1):24-32.
    View in: PubMed
    Score: 0.059
  18. Feasibility of regional and global left ventricular shape analysis from real-time 3d echocardiography. Annu Int Conf IEEE Eng Med Biol Soc. 2009; 2009:3641-4.
    View in: PubMed
    Score: 0.052
  19. Real-time 3-dimensional color Doppler flow of mitral and tricuspid regurgitation: feasibility and initial quantitative comparison with 2-dimensional methods. J Am Soc Echocardiogr. 2007 Sep; 20(9):1050-7.
    View in: PubMed
    Score: 0.047
  20. Automated interpretation of regional left ventricular wall motion from cardiac magnetic resonance images. J Cardiovasc Magn Reson. 2006; 8(3):427-33.
    View in: PubMed
    Score: 0.042
  21. Quantitative diagnosis of stress-induced myocardial ischemia using analysis of contrast echocardiographic parametric perfusion images. Eur J Echocardiogr. 2006 Jun; 7(3):217-25.
    View in: PubMed
    Score: 0.042
  22. Harmonic imaging for endocardial visualization and myocardial contrast echocardiography during transesophageal echocardiography. J Am Soc Echocardiogr. 2004 Jan; 17(1):10-4.
    View in: PubMed
    Score: 0.037
  23. Accuracy of mitral valve area measurements using transthoracic rapid freehand 3-dimensional scanning: comparison with noninvasive and invasive methods. J Am Soc Echocardiogr. 2003 Dec; 16(12):1292-300.
    View in: PubMed
    Score: 0.037
  24. Quantification of regional myocardial perfusion using semiautomated translation-free analysis of contrast-enhanced power modulation images. J Am Soc Echocardiogr. 2003 Feb; 16(2):116-23.
    View in: PubMed
    Score: 0.035
  25. Prolapsing aortic dissection. Echocardiography. 2001 Jul; 18(5):391.
    View in: PubMed
    Score: 0.031
  26. Detection of regional temporal abnormalities in left ventricular function during acute myocardial ischemia. Am J Physiol Heart Circ Physiol. 2001 Apr; 280(4):H1770-81.
    View in: PubMed
    Score: 0.031
  27. Effects of aging on left atrial reservoir, conduit, and booster pump function: a multi-institution acoustic quantification study. Heart. 2001 Mar; 85(3):272-7.
    View in: PubMed
    Score: 0.030
  28. Objective evaluation of regional left ventricular wall motion during dobutamine stress echocardiographic studies using segmental analysis of color kinesis images. J Am Coll Cardiol. 1999 Aug; 34(2):409-19.
    View in: PubMed
    Score: 0.027
  29. Acoustic quantification indexes of left ventricular size and function: effects of signal averaging. J Am Soc Echocardiogr. 1998 Aug; 11(8):792-802.
    View in: PubMed
    Score: 0.025
  30. Real-time 3D echocardiographic quantification of left atrial volume: multicenter study for validation with CMR. JACC Cardiovasc Imaging. 2012 Aug; 5(8):769-77.
    View in: PubMed
    Score: 0.017
  31. Three-dimensional analysis of regional left ventricular endocardial curvature from cardiac magnetic resonance images. Magn Reson Imaging. 2011 May; 29(4):516-24.
    View in: PubMed
    Score: 0.015
  32. Combined assessment of coronary anatomy and myocardial perfusion using multidetector computed tomography for the evaluation of coronary artery disease. Am J Cardiol. 2009 Jun 01; 103(11):1487-94.
    View in: PubMed
    Score: 0.013
  33. Automated frame-by-frame endocardial border detection from cardiac magnetic resonance images for quantitative assessment of left ventricular function: validation and clinical feasibility. J Magn Reson Imaging. 2009 Mar; 29(3):560-8.
    View in: PubMed
    Score: 0.013
  34. Semi-automated analysis of dynamic changes in myocardial contrast from real-time three-dimensional echocardiographic images as a basis for volumetric quantification of myocardial perfusion. Eur J Echocardiogr. 2009 Jun; 10(4):485-90.
    View in: PubMed
    Score: 0.013
  35. Quantitative assessment of left ventricular volume and ejection fraction using two-dimensional speckle tracking echocardiography. Eur J Echocardiogr. 2009 Jan; 10(1):82-8.
    View in: PubMed
    Score: 0.013
  36. Improved semiautomated quantification of left ventricular volumes and ejection fraction using 3-dimensional echocardiography with a full matrix-array transducer: comparison with magnetic resonance imaging. J Am Soc Echocardiogr. 2005 Aug; 18(8):779-88.
    View in: PubMed
    Score: 0.010
  37. Improved quantification of left ventricular volumes and mass based on endocardial and epicardial surface detection from cardiac MR images using level set models. J Cardiovasc Magn Reson. 2005; 7(3):595-602.
    View in: PubMed
    Score: 0.010
  38. Biplane stress echocardiography using a prototype matrix-array transducer. J Am Soc Echocardiogr. 2003 Sep; 16(9):937-41.
    View in: PubMed
    Score: 0.009
  39. Objective assessment of left ventricular wall motion from contrast-enhanced power modulation images. J Am Soc Echocardiogr. 2002 Feb; 15(2):118-28.
    View in: PubMed
    Score: 0.008
  40. Comparison of technetium-99m sestamibi-gated tomographic perfusion imaging with echocardiography and electrocardiography for determination of left ventricular mass. Am J Cardiol. 1996 Apr 01; 77(9):750-5.
    View in: PubMed
    Score: 0.005