Emil Sidky to Humans
This is a "connection" page, showing publications Emil Sidky has written about Humans.
Connection Strength
0.207
-
Report on the AAPM deep-learning spectral CT Grand Challenge. Med Phys. 2024 Feb; 51(2):772-785.
Score: 0.029
-
How little data is enough? Phase-diagram analysis of sparsity-regularized X-ray computed tomography. Philos Trans A Math Phys Eng Sci. 2015 Jun 13; 373(2043).
Score: 0.017
-
Compressive sensing in medical imaging. Appl Opt. 2015 Mar 10; 54(8):C23-44.
Score: 0.016
-
Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms. Med Phys. 2009 Nov; 36(11):4920-32.
Score: 0.011
-
Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Phys Med Biol. 2008 Sep 07; 53(17):4777-807.
Score: 0.010
-
Theory and algorithms for image reconstruction on chords and within regions of interest. J Opt Soc Am A Opt Image Sci Vis. 2005 Nov; 22(11):2372-84.
Score: 0.009
-
Minimum data image reconstruction algorithms with shift-invariant filtering for helical, cone-beam CT. Phys Med Biol. 2005 Apr 21; 50(8):1643-57.
Score: 0.008
-
Accurate Reconstruction of Multiple Basis Images Directly From Dual Energy CT Data. IEEE Trans Biomed Eng. 2024 Jul; 71(7):2058-2069.
Score: 0.008
-
Impact of polychromatic x-ray sources on helical, cone-beam computed tomography and dual-energy methods. Phys Med Biol. 2004 Jun 07; 49(11):2293-303.
Score: 0.008
-
Simultaneous Activity and Attenuation Estimation in TOF-PET With TV-Constrained Nonconvex Optimization. IEEE Trans Med Imaging. 2024 Jun; 43(6):2347-2357.
Score: 0.008
-
Prototyping optimization-based image reconstructions from limited-angular-range data in dual-energy CT. Med Image Anal. 2024 Jan; 91:103025.
Score: 0.007
-
Constrained one-step material decomposition reconstruction of head CT data from a silicon photon-counting prototype. Med Phys. 2023 Oct; 50(10):6008-6021.
Score: 0.007
-
Directional-TV algorithm for image reconstruction from limited-angular-range data. Med Image Anal. 2021 05; 70:102030.
Score: 0.006
-
Optimization-Based Image Reconstruction From Low-Count, List-Mode TOF-PET Data. IEEE Trans Biomed Eng. 2018 04; 65(4):936-946.
Score: 0.005
-
Image reconstruction and scan configurations enabled by optimization-based algorithms in multispectral CT. Phys Med Biol. 2017 Nov 02; 62(22):8763-8793.
Score: 0.005
-
Investigating simulation-based metrics for characterizing linear iterative reconstruction in digital breast tomosynthesis. Med Phys. 2017 Sep; 44(9):e279-e296.
Score: 0.005
-
Optimization-based image reconstruction with artifact reduction in C-arm CBCT. Phys Med Biol. 2016 10 21; 61(20):7300-7333.
Score: 0.005
-
Investigation of optimization-based reconstruction with an image-total-variation constraint in PET. Phys Med Biol. 2016 08 21; 61(16):6055-84.
Score: 0.004
-
Algorithm-enabled exploration of image-quality potential of cone-beam CT in image-guided radiation therapy. Phys Med Biol. 2015 Jun 21; 60(12):4601-33.
Score: 0.004
-
Noise properties of CT images reconstructed by use of constrained total-variation, data-discrepancy minimization. Med Phys. 2015 May; 42(5):2690-8.
Score: 0.004
-
Task-based optimization of dedicated breast CT via Hotelling observer metrics. Med Phys. 2014 Oct; 41(10):101917.
Score: 0.004
-
Investigation of iterative image reconstruction in low-dose breast CT. Phys Med Biol. 2014 Jun 07; 59(11):2659-85.
Score: 0.004
-
Comparison of human and Hotelling observer performance for a fan-beam CT signal detection task. Med Phys. 2013 Mar; 40(3):031104.
Score: 0.004
-
Optimization-based image reconstruction from sparse-view data in offset-detector CBCT. Phys Med Biol. 2013 Jan 21; 58(2):205-30.
Score: 0.004
-
Optimization-based reconstruction of sparse images from few-view projections. Phys Med Biol. 2012 Aug 21; 57(16):5245-73.
Score: 0.003
-
Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT. Phys Med Biol. 2010 Nov 21; 55(22):6575-99.
Score: 0.003
-
Accurate image reconstruction from few-view and limited-angle data in diffraction tomography. J Opt Soc Am A Opt Image Sci Vis. 2008 Jul; 25(7):1772-82.
Score: 0.003
-
Region of interest reconstruction from truncated data in circular cone-beam CT. IEEE Trans Med Imaging. 2006 Jul; 25(7):869-81.
Score: 0.002
-
Partial volume and aliasing artefacts in helical cone-beam CT. Phys Med Biol. 2004 Jun 07; 49(11):2365-75.
Score: 0.002
-
Short-scan SPECT imaging with non-uniform attenuation and 3D distance-dependent spatial resolution. Phys Med Biol. 2002 Aug 07; 47(15):2811-33.
Score: 0.002
-
The use of fluorescent dye for detecting the relative sealing efficiency of various root canal sealers. Part IV: Effect of retrofilling procedure on the sealing efficiency of endomethasone. Egypt Dent J. 1974 Oct; 20(4):1-12.
Score: 0.001
-
Plastic surgery of the mouth. J Egypt Med Assoc. 1952; 35(11-12):821-5.
Score: 0.000