The University of Chicago Header Logo

Connection

Valluvan Jeevanandam to Heart Ventricles

This is a "connection" page, showing publications Valluvan Jeevanandam has written about Heart Ventricles.
Connection Strength

1.890
  1. Yes, minimally invasive left ventricular device implantation can be done-but should it? J Thorac Cardiovasc Surg. 2016 11; 152(5):1448-1449.
    View in: PubMed
    Score: 0.368
  2. Technique for left ventricular apical cannulation for short-term mechanical circulatory support. Ann Thorac Surg. 2010 Mar; 89(3):994-5.
    View in: PubMed
    Score: 0.236
  3. Anemia and outcomes following left ventricular assist device implantation. Artif Organs. 2022 Aug; 46(8):1626-1635.
    View in: PubMed
    Score: 0.136
  4. A model for continued LVAD patient success: A 4-year readmission-free HeartMate 3 postoperative course. J Card Surg. 2021 Mar; 36(3):1159-1161.
    View in: PubMed
    Score: 0.126
  5. Short-Term Ventricular Structural Changes Following Left Ventricular Assist Device Implantation. ASAIO J. 2021 02 01; 67(2):169-176.
    View in: PubMed
    Score: 0.126
  6. Perioperative improvement in serum albumin level in patients with left ventricular assist device. J Card Surg. 2020 Nov; 35(11):3070-3077.
    View in: PubMed
    Score: 0.123
  7. Outflow Cannula Systolic Slope in Patients With Left Ventricular Assist Devices: A Novel Marker of Myocardial Contractility. ASAIO J. 2019 02; 65(2):160-166.
    View in: PubMed
    Score: 0.110
  8. Decoupling Between Diastolic Pulmonary Arterial Pressure and Pulmonary Arterial Wedge Pressure at Incremental Left Ventricular Assist Device (LVAD) Speeds Is Associated With Worse Prognosis After LVAD Implantation. J Card Fail. 2018 Sep; 24(9):575-582.
    View in: PubMed
    Score: 0.106
  9. Echocardiographic Predictors of Hemodynamics in Patients Supported With Left Ventricular Assist Devices. J Card Fail. 2018 Sep; 24(9):561-567.
    View in: PubMed
    Score: 0.106
  10. Cannula and Pump Positions Are Associated With Left Ventricular Unloading and Clinical Outcome in Patients With HeartWare Left Ventricular Assist Device. J Card Fail. 2018 03; 24(3):159-166.
    View in: PubMed
    Score: 0.100
  11. 3D Morphological Changes in LV and RV During LVAD Ramp Studies. JACC Cardiovasc Imaging. 2018 02; 11(2 Pt 1):159-169.
    View in: PubMed
    Score: 0.097
  12. Failure modes of left ventricular reconstruction or the Dor procedure: a multi-institutional perspective. Eur J Cardiothorac Surg. 2006 Aug; 30(2):347-52.
    View in: PubMed
    Score: 0.046
  13. Optimal cannula positioning of HeartMate 3 left ventricular assist device. Artif Organs. 2020 Dec; 44(12):e509-e519.
    View in: PubMed
    Score: 0.030
  14. HVAD Flow Waveform Estimates Left Ventricular Filling Pressure. J Card Fail. 2020 Apr; 26(4):342-348.
    View in: PubMed
    Score: 0.029
  15. Estimation of Central Venous Pressure by Pacemaker Lead Impedances in Left Ventricular Assist Device Patients. ASAIO J. 2020 01; 66(1):49-54.
    View in: PubMed
    Score: 0.029
  16. Association of Inflow Cannula Position with Left Ventricular Unloading and Clinical Outcomes in Patients with HeartMate II Left Ventricular Assist Device. ASAIO J. 2019 May/Jun; 65(4):331-335.
    View in: PubMed
    Score: 0.028
  17. Residual native left ventricular function optimization using quantitative 3D echocardiographic assessment of rotational mechanics in patients with left ventricular assist devices. Echocardiography. 2018 10; 35(10):1606-1615.
    View in: PubMed
    Score: 0.026
  18. HVAD Waveform Analysis as a Noninvasive Marker of Pulmonary Capillary Wedge Pressure: A First Step Toward the Development of a Smart Left Ventricular Assist Device Pump. ASAIO J. 2018 Jan/Feb; 64(1):10-15.
    View in: PubMed
    Score: 0.025
  19. G protein-coupled receptor kinase-2 is a novel regulator of collagen synthesis in adult human cardiac fibroblasts. J Biol Chem. 2011 Apr 29; 286(17):15507-16.
    View in: PubMed
    Score: 0.016
  20. Live 3-dimensional transesophageal echocardiography initial experience using the fully-sampled matrix array probe. J Am Coll Cardiol. 2008 Aug 05; 52(6):446-9.
    View in: PubMed
    Score: 0.013
  21. L-type Ca2+ channel alpha 1c subunit isoform switching in failing human ventricular myocardium. J Mol Cell Cardiol. 2000 Jun; 32(6):973-84.
    View in: PubMed
    Score: 0.008
  22. Radiofrequency ablation of Wolff-Parkinson-White syndrome in a donor heart after orthotopic heart transplantation. J Heart Lung Transplant. 1994 Sep-Oct; 13(5):905-9.
    View in: PubMed
    Score: 0.005
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.