Takeyoshi Ota to Follow-Up Studies
This is a "connection" page, showing publications Takeyoshi Ota has written about Follow-Up Studies.
Connection Strength
0.581
-
Impact of Residual Valve Disease on Survival After Implantation of Left Ventricular Assist Devices. Ann Thorac Surg. 2018 12; 106(6):1789-1796.
Score: 0.099
-
Short-term outcomes in adult cardiac surgery in the use of del Nido cardioplegia solution. Perfusion. 2016 Jan; 31(1):27-33.
Score: 0.080
-
Midterm surgical outcomes of noncomplicated active native multivalve endocarditis: single-center experience. Ann Thorac Surg. 2011 May; 91(5):1414-9.
Score: 0.060
-
Surgical treatment for Kommerell's diverticulum. J Thorac Cardiovasc Surg. 2006 Mar; 131(3):574-8.
Score: 0.042
-
Impact of worsening of aortic insufficiency during HeartMate 3 LVAD support. Artif Organs. 2021 Mar; 45(3):297-302.
Score: 0.029
-
Effect of Concomitant Tricuspid Valve Surgery With Left Ventricular Assist Device Implantation. Ann Thorac Surg. 2020 09; 110(3):918-924.
Score: 0.028
-
HeartWare Ventricular Assist Device Cannula Position and Hemocompatibility-Related Adverse Events. Ann Thorac Surg. 2020 09; 110(3):911-917.
Score: 0.028
-
Intraoperative Use of Nondepolarizing Neuromuscular Blocking Agents During Cardiac Surgery and Postoperative Pulmonary Complications: A Prospective Randomized Trial. J Cardiothorac Vasc Anesth. 2019 Jun; 33(6):1673-1681.
Score: 0.025
-
Left Atrial Appendage Occlusion With Left Ventricular Assist Device Decreases Thromboembolic Events. Ann Thorac Surg. 2019 04; 107(4):1181-1186.
Score: 0.025
-
Decoupling Between Diastolic Pulmonary Arterial Pressure and Pulmonary Arterial Wedge Pressure at Incremental Left Ventricular Assist Device (LVAD) Speeds Is Associated With Worse Prognosis After LVAD Implantation. J Card Fail. 2018 Sep; 24(9):575-582.
Score: 0.025
-
Echocardiographic Predictors of Hemodynamics in Patients Supported With Left Ventricular Assist Devices. J Card Fail. 2018 Sep; 24(9):561-567.
Score: 0.025
-
Long-Acting Octreotide Reduces the Recurrence of Gastrointestinal Bleeding in Patients With a Continuous-Flow Left Ventricular Assist Device. J Card Fail. 2018 Apr; 24(4):249-254.
Score: 0.024
-
Consequences of Retained Defibrillator and Pacemaker Leads After Heart Transplantation-An Underrecognized Problem. J Card Fail. 2018 02; 24(2):101-108.
Score: 0.024
-
Cannula and Pump Positions Are Associated With Left Ventricular Unloading and Clinical Outcome in Patients With HeartWare Left Ventricular Assist Device. J Card Fail. 2018 03; 24(3):159-166.
Score: 0.023
-
Bridge-to-decision therapy with a continuous-flow external ventricular assist device in refractory cardiogenic shock of various causes. Circ Heart Fail. 2014 Sep; 7(5):799-806.
Score: 0.019
-
Newly developed tissue-engineered material for reconstruction of vascular wall without cell seeding. Ann Thorac Surg. 2009 Oct; 88(4):1269-76.
Score: 0.013
-
Minimally invasive epicardial left atrial ablation and appendectomy for refractory atrial tachycardia. Ann Thorac Surg. 2008 Oct; 86(4):1375-7.
Score: 0.013